Chapter 13 Signal Source

RIGOL

MSO2000A/DS2000A User’s Guide

13-15

2. Interpolation

Press Interp to turn on or off the interpolation mode between the points of the
waveform.
ON: the waveform editor connects two points using a straight line.

OFF: the waveform editor will keep a constant voltage level between the

two points and create a ladder-like waveform.

3. Zoom

Press Zoom to turn on or off the zoom function.
ON: the waveform editing window only displays the current point.
OFF: the waveform editing window displays all the initial points.


4. Current Point

Press Current and use

or the navigation knob to select the point to be

edited. The range is from 1 to the initial points. For the setting method, please
refer to the introduction in Parameter Setting Method.

5. Voltage

Press Voltage and use

or the navigation knob to set the voltage of the

current point. The range is from -2.5 V to +2.5 V. For the setting method, please
refer to the introduction in Parameter Setting Method.

6. Time

Press Time and use

or the navigation knob to set the duration of the current

Advertising