RIGOL MSO/DS2000A Series User Manual

Page 51

Advertising
background image

Chapter 1 Quick Start

RIGOL

MSO2000A/DS2000A User’s Guide

1-23

9. Trigger Type

Display the currently selected trigger type and trigger condition setting.
Different labels are displayed when different trigger types are selected.
For example: represents triggering on the rising edge in “Edge” trigger.

10. Trigger Source

Display the trigger source currently selected (CH1, CH2, EXT, AC Line or any
channel of D0-D15). Different labels are displayed when different trigger
sources are selected and the color of the trigger parameter area will change
accordingly.
For example, denotes that CH1 is selected as the trigger source.

11. Trigger Level

 When the trigger source is set to CH1 or CH2, the trigger level label

is

displayed at the right of the screen and the trigger level value is displayed at
the upper-right corner of the screen. When using TRIGGER

LEVEL to

modify the trigger level, the trigger level value will change with the up and
down of

.

 When the trigger source is EXT, the trigger level value is displayed at the

upper-right corner of the screen. No trigger level label is displayed.

 If the trigger source is AC line, no trigger level value and trigger level label

are displayed.

 When the trigger source is set to D0 to D15, the trigger level is displayed at

the upper-right corner of the screen. No trigger level label is displayed.

 In Runt trigger, slope trigger and windows trigger, two trigger level labels

( and

) are displayed.


12. CH1 Vertical Scale

Display the voltage value per grid of CH1 waveform vertically. In addition, the
following labels will be displayed according to the current channel setting:
channel coupling (e.g. ), input impedance (e.g. ) and bandwidth limit (e.g.

). You can use VIRTICAL SCALE to modify this parameter.

13. Analog Channel Label/Waveform

Different channels are marked with different colors and the colors of the channel
label and waveform are the same.

Advertising