To output basic waveform, To output sine, To output basic waveform -3 – RIGOL MSO/DS2000A Series User Manual

Page 227: To output sine -3

Advertising
background image

Chapter 13 Signal Source

RIGOL

MSO2000A/DS2000A User’s Guide

13-3

To Output Basic Waveform

To Output Sine


Press Setup1 to open the waveform setting menu. Press Wave and select “Sine”. At
this point, you can set the sine parameters.

1. Source

Press Source to turn on or off the signal output.

2. Set the frequency

Press Freq to set the frequency of the signal. The range is from 100 mHz to 25
MHz.

Note:

For different waveforms, the frequency ranges are different. The

frequency range of square is from 100 mHz to 15 MHz; the frequency range of
pulse is from 100 mHz to 1 MHz; the frequency range of ramp is from 100 mHz to
100 kHz. For the setting method, please refer to the introduction in Parameter
Setting Method
.


3. Set the amplitude

Press Amp to set the amplitude of the signal. When the impedance is set to
HighZ, the range is from 20 mVpp to 5 Vpp; when the impedance is set to 50 Ω,
the range is from 10 mVpp to 2.5 Vpp. For the setting method, please refer to the
introduction in

Parameter Setting Method.

4. Set the DC offset voltage

Press Offset to set the DC offset of the signal. When the impedance is HighZ,
the range is from (-2.5 V+the current amplitude/2) to (2.5 V-the current
amplitude/2); when the impedance is set to 50 Ω, the range is from (-1.25 V+the
current amplitude/2) to (1.25 V-the current amplitude/2). For the setting method,
please refer to the introduction in

Parameter Setting Method.

Note:

The offset value only contains three effective digits. For example, when

the amplitude is set to 30 mVpp (the impedance is 50 Ω), the offset range
calculated is from -1.235 V to 1.235 V, while the actual offset range is -1.23 V to
1.23 V.

Advertising