RIGOL MSO/DS2000A Series User Manual

Page 107

Advertising
background image

Chapter 5 To Trigger the Oscilloscope

RIGOL

MSO2000A/DS2000A User’s Guide

5-21

: trigger when the negative slope time of the input signal is greater than

the specified time.

: trigger when the negative slope time of the input signal is lower than

the specified time.

: trigger when the negative slope time of the input signal is greater than

the specified lower limit of time and lower than the specified upper limit of time.


Time Setting:
 When the Slope Condition is set to

,

,

or

,

press Time and use

or the navigation knob to input the desired value. The

range available is from 10 ns to 1 s.

 When the Slope Condition is set to

or

, press Upper Limit

and Lower Limit and use

or the navigation knob to input the desired

values respectively. The range of time upper limit is from 20 ns to 1 s. The range
of the time lower limit is from 10 ns to 999 ms.

Note:

The time lower limit must be lower than the upper limit.


Vertical Window and Trigger Level:
After the trigger condition setting is completed, adjust the trigger level using
TRIGGER LEVEL to correctly trigger the signal and obtain stable waveform. The
adjustment mode of the trigger level is different when different vertical window is
selected in slope trigger. Press Vertical and use

to select the desired vertical

window or press down Vertical continuously to switch the vertical window. You can
choose to only adjust the upper limit, the lower limit or both of them.

: only adjust the upper limit of the trigger level. During the adjustment,

“UP Level” and “Slew Rate” change accordingly but “Low Level” remains
unchanged.

: only adjust the lower limit of the trigger level. During the adjustment,

“Low Level” and “Slew Rate” change accordingly but “UP Level” remains
unchanged.

: adjust the upper and lower limits of the trigger level at the same time.

During the adjustment, “UP Level” and “Low Level” change accordingly but
“Slew Rate” remains unchanged.


When the Slope Condition is set to

,

,

, or

, the

current trigger level and slew rate will be displayed at the lower left corner of the
screen, as shown in figure 5-5 (a). The formula of slew rate is:

Advertising