Specifications, Chapter 18 specifications -1, Chapter 18 specifications – RIGOL MSO/DS2000A Series User Manual

Page 299

Advertising
background image

Chapter 18 Specifications

RIGOL

MSO2000A/DS2000A User’s Guide

18-1

Chapter 18 Specifications


All the specifications are guaranteed except the parameters marked with “Typical”
and the oscilloscope needs to operate for more than 30 minutes under the specified
operation temperature.

Sample

Sample Mode

Real-time Sample

Real Time
Sample Rate

Analog channe: 2 GSa/s (single-channel), 1 Gsa/s (dual-channel)
Digital channel: 1 GSa/s (max)

Peak Detect

Analog channe: 500 ps (single-channel), 1 ns (dual-channel)
Digital channel: 2 ns

Averaging

After both the channels finish N samples at the same time, N can
be 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024, 2048, 4096 or 8192.

High
Resolution

12 bits of resolution when ≥5 μs/div @ 1 GSa/s (or ≥10 μs/div @
500 MSa/s).

Min Detect
Pulse Width

Digital channel: 5 ns

Memory Depth

Analog channel:
single-channel: Auto, 14k pts, 140k pts, 1.4M pts, 14M pts and
56M pts (option) are available
dual-channel: Auto, 7k pts, 70k pts, 700k pts, 7M pts and 28M pts
(option) are available
Digital channel: 14M pts maximum


Input

Number of
Channels

MSO2XX2A/2XX2A-S: 2 analog channels+16 digital channels
DS2XX2A/2XX2A-S: 2 analog channels

Input Coupling DC, AC or GND
Input
Impedance

Analog channe: (1 MΩ±1%) || (16 pF±3 pF) or 50 Ω±1.5%
Digital channel: (101 kΩ±1%)||(9 pF±1 pF)

Probe
Attenuation
Coefficient

Analog channe: 0.01X to 1000X, in 1-2-5 step