Can decoding (option), Can decoding (option) -17 – RIGOL MSO/DS2000A Series User Manual

Page 195

Advertising
background image

Chapter 8 Protocol Decoding

RIGOL

MSO2000A/DS2000A User’s Guide

8-17

CAN Decoding (Option)


Press Decode1Decode and select “CAN” to open the CAN decoding function
menu.

1. Source

Press Source and select any channel (CH1, CH2 or any channel of D0-D15) as
the source channel.
If the source channel is set to CH1 or CH2, press Threshold to set the threshold
of the source channel. The range of the threshold is decided by the vertical
position and scale, and is from (-5 * vertical scale - vertical position) to (5 *
vertical scale - vertical position). If the data channel is set to any channel of
D0-D15, Threshold will be hidden automatically.

2. Signal Type

Press Signal Type to select the desired signal type.

Rx:the received signal from the CAN signal line.
Tx:the sending signal from the CAN signal line.
CAN_H: the actual CAN_H bus signal.
CAN_L: the actual CAN_L bus signal.
Differential: the CAN differential bus signals connected to an analog

channel using a differential probe. The positive lead of the probe connects
the CAN_H bus signal and the negative lead connects the CAN_L bus signal.

3. Baud

Press Baud to select a baud rate (100 kb/s, 125 kb/s, 250 kb/s, 400 kb/s, 500
kb/s (default), 800 kb/s, 1 Mb/s or User) that matches the CAN bus signal. When
“User” is selected, press Setup and use

or the nevigation knob to enter the

desired rate. The range is from 10 kb/s to 1 Mb/s.

4. Sample Point

The Sample point is a point within a bit’s time. The oscilloscope samples the bit
level at this point. “Sample point” is represented by the percentage of “the time
from the start of the bit’s time to the sample point time” in the “bit’s time”.
Press Sample Point and use

to adjust this parameter with a step of 1%.

The range is from 5% to 95% and the default is 50%.