To output noise, To output noise -7 – RIGOL MSO/DS2000A Series User Manual

Page 231

Advertising
background image

Chapter 13 Signal Source

RIGOL

MSO2000A/DS2000A User’s Guide

13-7

To Output Noise


Press Setup1 to open the waveform setting menu. Press Wave and select “Noise”.
At this point, you can output noise signal with specified amplitude.

1. Set the amplitude

Press Amp to set the amplitude of the signal. When the impedance is set to
HighZ, the range is from 20 mVpp to 5 Vpp; when the impedance is set to 50 Ω,
the range is from 10 mVpp to 2.5 Vpp. For the setting method, please refer to the
introduction in

Parameter Setting Method.

2. Set the offset

Press Offset to set the DC offset of the noise signal. When the impedance is
HighZ, the range is from (-2.5 V+the current amplitude/2) to (2.5 V-the current
amplitude/2); when the impedance is set to 50 Ω, the range is from (-1.25 V+the
current amplitude/2) to (1.25 V-the current amplitude/2). For the setting method,
please refer to the introduction in

Parameter Setting Method.

Note:

The offset value only contains three effective digits. For example, when

the amplitude is set to 30 mVpp (the impedance is 50 Ω), the offset range
calculated is from -1.235 V to 1.235 V, while the actual offset range is from -1.23
V to 1.23 V.