Diagnostics and Troubleshooting

MVI56-PDPMV1 ♦ ControlLogix Platform

User Manual

PROFIBUS DPV1 Master

Page 192 of 255

ProSoft Technology, Inc.

March 22, 2011

Viewing Control Registers
Press [3] to view information about the PROFIBUS Master’s Control Registers.

Use this command to view general information about the module, such as the

firmware version and its serial number. The module status contains two possible

codes:
 0400 = module is running but not communicating with slaves
 0401 = module is running and communicating with slaves
If the module is in STOP mode, the status code is displayed as 0400.

Exiting the Program
Press [ESC]

to restart the module and force all drivers to be loaded. The module

will use the configuration stored in the module's flash memory to configure the

module.

Input Database View Menu
Press [I] from the Main Menu to open the Input Database View menu. Use this

menu command to view the current contents of the module’s database. Press [?]
to view a list of commands available on this menu.

Displaying the Current Page of Registers Again
Press [S]

from the Database View menu to show the current page of registers

again.

This screen displays the current page of 100 registers in the database.