MVI56-PDPMV1 ♦ ControlLogix Platform
Configuring the MVI56-PDPMV1 Module
PROFIBUS DPV1 Master
User Manual
ProSoft Technology, Inc.
Page 89 of 255
March 22, 2011
4 In the tree view, click the plus sign
[+]
to expand the slave device you added.
This action opens a list of device configuration values. The following
illustration shows the possible input/output configuration values for a Siemens
EM 277 PLC Slave. The selections available for other devices will be
different, so you should review the specifications for the product you are
installing in order to determine the correct values to use.
5 Drag the input and output parameters to the Slot Location Grid (Subscriber
List) below the Bus Configuration window. This view displays the slot number,
configuration data, and starting input and output addresses. The MVI56-
PDPMV1 Master uses this information to identify and communicate with
individual slaves on the network.