ProSoft Technology MVI56-PDPMV1 User Manual

Page 233

Advertising
background image

MVI56-PDPMV1 ♦ ControlLogix Platform

Reference

PROFIBUS DPV1 Master

User Manual

ProSoft Technology, Inc.

Page 233 of 255

March 22, 2011

Byte Offset

Start

End

Name

Description

58

73

PROFIBUS Slave
Diagnostic Status

This is a 16-byte array with bit fields where one bit is assigned to
each slave station address. When a slave leaves the "Deactive"
state for the first time, the associated bit is set. This bit is then
cleared when the slave enters "Data Exchange" state. If a slave
indicates "Extended Diagnostics" when it is in "Data Exchange"
state, the associated bit is set. For the bit/slave relationship,
refer to the Slave List Structure below.

Slave List Structure

Byte Offset

Start

End

Name

Description

74

74

PROFIBUS pad byte to make data word aligned (not used)

75

75

PROFIBUS Master
Operating State

PROFIBUS Master operating state
0x0000=Offline
0x4000=Stop
0x8000=Clear
0xC000=Operate

76

77

PROFIBUS Ident
Number

PROFIBUS Master PNO Ident number. Bytes will be swapped

78

81

PROFIBUS Master
Serial Number

Unique 32-bit serial number for the PROFIBUS Master

82

83

PROFIBUS Software
Version

Software version number for the PROFIBUS Master software
Example for Version 1.40:
High Byte - 0x40
Low Byte - 0x01