MVI56-PDPMV1 ♦ ControlLogix Platform

Configuring the MVI56-PDPMV1 Module

PROFIBUS DPV1 Master

User Manual

ProSoft Technology, Inc.

Page 93 of 255

March 22, 2011

When the download is completed, the PROFIBUS Master Configuration window

will initialize the Master to operate as a Class 2 Master only. In this mode it is

possible to initialize the Master even if the database does not contain any slaves.
After successful initialization, the PROFIBUS Master Configuration window will

issue the following mailboxes in order to gather information about the connected

slaves:
1 1. Send FB_APPL_GET_LIVE_LIST in order to detect connected slaves,
2 2. Send FB_APPL_GET_SLAVE_DIAG (external request) to all devices

identified as slaves according to the Live list.

3 3. Send FB_APPL_GET_SLAVE_CONFIG to all devices identified as slaves

according to the Live list.