Manage the oui table – NETGEAR M4350-24F4V 24-Port 10G SFP+ Managed AV Network Switch User Manual

Page 262

Advertising
background image

1 or Unit ID for a stacked switch:

-

1: If no switch stack is configured, the physical interfaces for the switch are
displayed.

-

Unit ID for a stacked switch: If a switch stack is configured, the physical
interfaces for the switch with the selected stack unit ID are displayed.

LAG: Only LAGs are displayed.

All: Both physical interfaces and LAGs are displayed, or for a switch stack, both
physical interfaces on all switches in the stack and LAGs are displayed.

7. Select one or more interfaces by taking one of the following actions:

To configure a single interface, select the check box associated with the port, or
type the port number in the Go To Interface field and click the Go button.

To configure multiple interfaces with the same settings, select the check box
associated with each interface.

To configure all interfaces with the same settings, select the check box in the
heading row.

8. From the Auto VoIP Mode menu, select to enable or disable the Auto VoIP mode

for the interface.

Auto-VoIP is disabled by default.

9. Click the Apply button.

Your settings are saved.

The Operational Status field show if the interface is up or down.

10. To save the settings to the running configuration, click the Save icon.

Manage the OUI table

Device hardware manufacturers can include an OUI in a network adapter to help identify
a hardware device. The OUI is a unique 24-bit number assigned by the IEEE registration
authority. The switch comes preconfigured with the following OUIs that identify the IP
phone manufacturer:

00:01:E3: SIEMENS

00:03:6B: CISCO1

00:12:43: CISCO2

00:0F:E2: H3C

00:60:B9: NITSUKO