Configure the port link flap settings – NETGEAR M4350-24F4V 24-Port 10G SFP+ Managed AV Network Switch User Manual

Page 355

Advertising
background image

Table 88. Port transceiver information

Description

Field

The port in which the transceiver module is installed.

Port

The vendor name of the transceiver module.

Vendor Name

The link length supported for 50 μm fiber.

Link Length 50 μm [m]

The link length supported for 62, 5 μm fiber.

Link Length 62, 5 μm [m]

The serial number of the transceiver module.

Serial Number

The part number of the transceiver module.

Part Number

The nominal signalling rate for the transceiver module.

Nominal Bit Rate [Mpbs]

The vendor revision of the transceiver module.

Revision

The compliance of the transceiver module.

Compliance

Indicates if the inserted transceiver module is actually supported (Yes or No).

Supported

The potential speed that the transceiver module can support.

Possible Speed Detected

Configure the port link flap settings

You can configure the port link flap settings, which determine when a port is automatically
placed in the disabled state. You can also configure the automatic recovery settings,
which allows a port to be automatically activated again.

To configure the port link flap settings:

1. Launch a web browser.

2. In the address field of your web browser, enter the IP address of the switch.

If you do not know the IP address of the switch, see Log in to the main UI with a web
browser
on page 27 and the subsections.

The login page displays.

3. Click the Main UI Login button.

The main UI login page displays in a new tab.

4. Enter admin as the user name, enter your local device password, and click the Login

button.

The first time that you log in, no password is required. However, you then must
specify a local device password to use each subsequent time that you log in.

The System Information page displays.

5. Select Switching > Ports > Link Flap Configuration.

The Link Flap Configuration page displays.

Main User Manual

355

Configure Switching Information

Fully Managed Switches M4350 Series Main User Manual

Advertising