Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual
Page 1076
1046
Fabric OS Command Reference
53-1003131-01
sfpShow
2
Temperature: Not Available
Current : Not Available
Voltage : Not Available
RX Power : Not Available
TX Power : Not Available
Last poll time: Polling has not started
To display detailed information about all SFPs:
switch:user> sfpshow -all
(output truncated)
=============
Slot 8/Port 50:
=============
=============
Slot 8/Port 51:
=============
=============
Slot 8/Port 52:
=============
QSFP No: 13 Channel No:0
Identifier: 13 QSFP+
Connector: 12 MPO Parallel Optic
Transceiver: 0000000000000000 16_Gbps id
Encoding: 5 64B66B
Baud Rate: 140 (units 100 megabaud)
Length 9u: 0 (units km)
Length 50u: 25 (units 2 meters)
Length 62.5u:0 (units 1 meter)
Length Cu: 0 (units 1 meter)
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-0000090-01
Vendor Rev: A
Wavelength: 850 (units nm)
Options: 00000fde
Max Case Temp: 70 (C)
Device Tech: 0x00
Serial No: HTA110491002833
Date Code: 101207
DD Type: 0x8
Enh Options: 0x0
Status/Ctrl: 0x0
Alarm flags[0,1] = 0x0, 0x0
Warn Flags[0,1] = 0x0, 0x0
Alarm Warn
low high low high
Temperature: 38 Centigrade -5 85 0 80
Current: 6.394 mAmps 0.500 10.000 1.000 9.500
Voltage: 3266.0 mVolts 2970.0 3630.0 3134.9 3465.0
RX Power: -0.1 dBm (977.0uW) 44.6 uW 2187.8 uW 112.2uW 1737.8uW
State transitions: 1
Last poll time: 02-03-2012 UTC Fri 07:36:05
(output trunctaed)