portShow

2

Compression: On (Aggressive)

Fastwrite: Off

Tape Acceleration: Off

TPerf Option: Off

IPSec: Disabled

QoS Percentages: High 50%, Med 30%, Low 20%

Remote WWN: Not Configured

Local WWN: 10:00:00:05:1e:a5:54:bd

Peer WWN: 00:00:00:00:00:00:00:00

Circuit Count: 4

Flags: 0x00000000

FICON: On

FICON XRC: Off

FICON Tape Write: On

FICON Tape Read: On

FICON TinTir Emul: On

FICON Dvc Acking: On

FICON Read BLK-ID: On

FICON Teradata Write: On

FICON Teradata Read: On

Tape Write Pipe: 63

Tape Read Pipe: 65

Tape Write Devs: 32

Tape Read Devs: 32

Tape Write Timer: 300

Tape Max Chain: 3200000

FICON OXID Base: 0x8000

FICON Debug Flags: 0xf7c90000

To display an FCIP tunnel with FICON disabled:

switch:admin> portshow fciptunnel 16

-------------------------------------------

Tunnel ID: 16

Tunnel Description:

Admin Status: Enabled

Oper Status: Up

Compression: On (Aggressive)

Fastwrite: Off

Tape Acceleration: Off

TPerf Option: Off

IPSec: Disabled

QoS Percentages: High 50%, Med 30%, Low 20%

Remote WWN: Not Configured

Local WWN: 10:00:00:05:1e:a5:54:bd

Peer WWN: 00:00:00:00:00:00:00:00

Circuit Count: 4

Flags: 0x00000000

FICON: Off

To display an FCIP tunnel with additional circuit information:

switch:admin> portshow fciptunnel 1/12 -c

Tunnel ID: 1/12

Tunnel Description:

Admin Status: Enabled

Oper Status: Up

Compression: Off

Fastwrite: Off

Tape Acceleration: Off

Advertising