Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual

Page 1078

Advertising
background image

1048

Fabric OS Command Reference

53-1003131-01

sfpShow

2

To display detailed information for GbE port 0 on a Brocade 7800 extension switch:

switch:admin> sfpshow ge0

Identifier: 3 SFP

Connector: 0

Transceiver: 0000000008000000 id

Encoding: 1 8B10B

Baud Rate: 13 (units 100 megabaud)

Length 9u: 0 (units km)

Length 9u: 0 (units 100 meters)

Length 50u: 0 (units 10 meters)

Length 62.5u:0 (units 10 meters)

Length Cu: 100 (units 1 meter)

Vendor Name: BROCADE

Vendor OUI: 00:05:1e

Vendor PN: 57-1000042-01

Vendor Rev: A

Wavelength: 0 (units nm)

Options: 0010 Tx_Disable

BR Max: 0

BR Min: 0

Serial No: CZA109302000053

Date Code: 090504

DD Type: 0x0

Enh Options: 0x0

To display detailed information about a QSFP:

switch:admin> sfpshow 8/0

QSFP No: 0 Channel No:0

Identifier: 13 QSFP+

Connector: 12 MPO Parallel Optic

Transceiver: 0000000000000004 10_Gbps id

Encoding: 5 64B66B

Baud Rate: 103 (units 100 megabaud)

Length 9u: 0 (units km)

Length 50u (OM3): 100 (units m)

Length 62.5u:0 (units m)

Vendor Name: BROCADE

Vendor OUI: 00:17:6a

Vendor PN: 57-1000042-01

Vendor Rev: 01

Wavelength: 850 (units nm)

Options: 00000fde

Max Case Temp: 70 C)

Device Tech: 0x00

Serial No: XXXXXX16

Date Code: 100722

DD Type: 0x8

Enh Options: 0x0

Status/Ctrl: 0x0

Alarm flags[0,1] = 0x0, 0x0

Warn Flags[0,1] = 0x0, 0x0

Alarm Warn

low high low high

Temperature: 36 Centigrade -5 75 0 70

Current: 6.132 mAmps 0.500 10.000 1.000 9.500

Advertising