portCfgShow

2

EXAMPLES

To display the port configuration settings for a single port on a Brocade DCX 8510-8:

switch:admin> portcfgshow 10/38

Area Number: 222

Octet Speed Combo: 1(16G|8G|4G|2G)

Speed Level: AUTO(HW)

AL_PA Offset 13: OFF

Trunk Port ON

Long Distance LS

VC Link Init OFF

Desired Distance 10 Km

Reserved Buffers 86

Locked L_Port OFF

Locked G_Port OFF

Disabled E_Port OFF

Locked E_Port OFF

ISL R_RDY Mode OFF

RSCN Suppressed OFF

Persistent Disable OFF

LOS TOV enable OFF

NPIV capability ON

NPIV FLOGI Logout ON

QOS E_Port AE

Port Auto Disable: ON LOSG OLS NOS LIP

Rate Limit OFF

EX Port OFF

Mirror Port OFF

SIM Port ON

Credit Recovery ON

F_Port Buffers OFF

E_Port Credits OFF

Fault Delay: 0(R_A_TOV)

NPIV PP Limit: 126

CSCTL mode: OFF

D-Port mode: ON

D-Port over DWDM: ON

Compression: OFF

Encryption: OFF

FEC: ON

To display the port configuration settings on a Brocade 5100 for a range of ports specified by their index
numbers:

switch:admin> portcfgshow -i 3-5

Speed 8G 8G 8G

Fill Word(On Active) 0 0 0

Fill Word(Current) 0 0 0

AL_PA Offset 13 .. .. ..

Trunk Port ON ON ON

Long Distance .. .. ..

VC Link Init .. .. ..

Locked L_Port .. .. ..

Locked G_Port .. .. ..

Disabled E_Port .. .. ..

Locked E_Port .. .. ..

ISL R_RDY Mode .. .. ..

RSCN Suppressed .. .. ..

Persistent Disable .. .. ..

LOS TOV enable ON .. ..

NPIV capability ON ON ON