80

Fabric OS Command Reference

53-1003131-01

bottleneckMon

2

6 seconds in an interval of 10 seconds, and 1 second out of the other 4 seconds was affected by a
bottleneck, the display for that interval would show 25% as the percentage of affected seconds (1 out of
4), and state "no data for 6 seconds." However, if there is no traffic because the port is offline, the "no
data..." message is displayed.

The --status option displays bottleneck configuration details for the current (logical) switch. If virtual
fabrics are enabled, ports not belonging to the current logical switch are not displayed. The command
output includes the following information:

Bottleneck detection

Enabled or disabled

Switch-wide sub-second latency bottleneck criterion

Displays the following parameters:

Time threshold

The value set with the -lsubsectimethresh operand.

Severity threshold

The value set with the -lsubsecsevthresh operand.

Switch-wide alerting parameters

Displays the following parameters:

Alerts?

Yes (enabled), No (disabled), Congestion only, or Latency only.

Congestion threshold for alert

The severity threshold for triggering a congestion alert. This threshold indicates
the percentage of one-second intervals affected by congestion conditions within a
specified time window. The congestion threshold is expressed as a fraction
between 0 and 1.

Latency threshold for alert

The severity threshold for triggering a latency alert. This threshold indicates the
percentage of one-second intervals affected by latency conditions within a
specified time window. The latency threshold is expressed as a fraction between 0
and 1.

Averaging time for alert

The time window in seconds over which the percentage of seconds affected by
bottleneck conditions is computed and compared with the threshold.

Quiet time for alert

The minimum number of seconds between consecutive alerts. The value
assigned to this parameter applies to both latency and congestion detection.

Per-port overrides for sub-second latency bottleneck criterion

Custom configuration for the above mentioned sub-second latency bottleneck
parameters. Note that everything above this line applies to all ports in the switch
that don't have any custom configuration or exclusions.

Per-port overrides for alert parameters

Custom configuration for the above mentioned alert parameters. The
abbreviations "C" and "L" indicate "congestion" and "latency" alerts. "Y" means
alerts are enabled for both types, and "N" means alerts are disabled.

Excluded ports

List of ports excluded from bottleneck detection.

For more information on the RASlog messages, refer to the Fabric OS Message Reference.