Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual

Page 818

Advertising
background image

788

Fabric OS Command Reference

53-1003131-01

portCfgQoS

2

To enable CS_CTL VC mode on a port when QoS is enabled:

switch:admin> portcfgqos --enable 1/10-16 csctl_mode

Enabling CSCTL mode flows causes QoS zone flows to \

lose priority on such ports

Do you want to proceed?(y/n): y

switch:admin> portcfgshow -slot 1

Index: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

--------------------+--+--+--+---+--+--+--+---+--+--+--+---+--+--+--+-

Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN

Fill Word(On Active)0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Fill Word(Current) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

AL_PA Offset 13 .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON

Long Distance .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

VC Link Init .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

Locked L_Port .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

Locked G_Port .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

Disabled E_Port .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

Locked E_Port .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

ISL R_RDY Mode .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

RSCN Suppressed .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

Persistent Disable .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

LOS TOV enable .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON

NPIV PP Limit

126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126

QOS Port AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE AE

EX Port ON ON .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Mirror Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Rate Limit .. .. .. . .. .. .. .. .. .. .. .. .. .. .. ..

Credit Recovery ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON

Fport Buffers .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Port Auto Disable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

CSCTL mode .. .. .. .. .. .. .. .. .. ON ON ON ON ON ON ON

D-Port mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..

Fault Delay 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

(output truncated)

To disable CS_CTL VC mode on a port range:

switch:admin> portcfgqos --disable 1/10-16 csctl_mode

SEE ALSO

portCfg

,

portCmd

,

portShow

,

switchShow

,

configure

Advertising