Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual

Page 441

Advertising
background image

Fabric OS Command Reference

411

53-1003131-01

flow

2

-egrport port

Specifies the egress port. The port can be in either [slot/]port or D,I format
depending on the port mode configured using the -portIdMode operand.

The -ingrport and -egrport options are mutually exclusive; that is, you can
specify only one of the options. The learning mode ("*") is not supported.

-mirrorport port

Specifies the port from which mirrored frames exits. The port can be in either
[slot/]port or D,I format depending on the port mode configured using the
-portIdMode operand.

frame_options

Specifies the options that represent the content of the FC frame or attributes of the
frame.

-srcdev device_id

Specifies the 3-byte source ID of the originator device. The device_id can be in
PID or PWWN format depending on the device ID mode configured using the
-deviceIdMode operand. The PID format is 0xDDAAPP, where DD is the Domain
ID, AA is the Area ID and PP is the AL_PA ID. The PWWN format is
"XX:XX:XX:XX:XX:XX:XX:XX". Specify "*" to enumerate all originator devices.

-dstdev device_id

Specifies the 3-byte destination ID of the destination device. The device_id can be
in PID or PWWN format depending on the device ID mode configured using the
-deviceIdMode operand. The PID format is 0xDDAAPP, where DD is the Domain
ID, AA is the Area ID and PP is the AL_PA ID. The PWWN format is
"XX:XX:XX:XX:XX:XX:XX:XX". Specify "*" to enumerate all destination devices.

-lun LUN_id

Specifies the LUN identification in decimal or hexadecimal (2-byte value) format.
The valid range for LUN_id is from 0 through 65535 (0x0000 to 0xFFFF). The
LUN parameter includes the addressing method and fields associated with the
respective addressing method. If the most significant byte (MSB) is not specified
in the flow definition, 0x00 is used. This operand is not supported by the Flow
Generator feature.

-frametype type

Specifies the predefined frame type. Valid values for type include the following:
SCSI, SCSIRead, SCSIWrite, SCSIRW, SCSI2Reserve, SCSI3Reserve,
scsicmdsts, ABTS, BAACC, SCSI2Release, SCSI3Release, SCSITur,
SCSI2ReserveRelease, SCSI3ReserveRelease, SCSIGoodStatus,
SCSICheckStatus, SCSIResvConflict, SCSIInquiry, SCSIXferrdy, and BARJT.
This operand is not supported by the Flow Generator feature.

config_options

Specifies the flow configuration options.

-bidir

Configures the features to act on both incoming and outgoing directions on
bidirectional traffic. For example, the Flow Mirror feature mirrors the frames on
both directions: traffic originating from the source device and traffic that is
destined to the source device. This operand is not supported by the Flow
Generator feature.

-noactivate

Allows a flow to be created, but suppresses activation of a flow.

-noconfig

Overrides the default behavior, which automatically saves the flow in the
persistent configuration when you create a flow. The flow will be lost when the
system is rebooted.