2

linkRLIRFailureIncident: NO

HA-TRAP: NO

fruStatusChanged: NO

cpStatusChanged: NO

fruHistoryTrap: NO

ISCSI-TRAP: NO

iscsiTgtLoginFailure: NO

iscsiIntrLoginFailure: NO

iscsiInstSessionFailure: NO

IF-TRAP: NO

linkDown: NO

linkUp: NO

BD-TRAP: NO

bdTrap: NO

bdClearTrap: NO

MAPS-TRAP: YES

mapsTrapAM: YES

T11-FC-ZONE-SERVER-TRAP: NO

t11ZsRequestRejectNotify: NO

t11ZsMergeFailureNotify: NO

t11ZsMergeSuccessNotify: NO

t11ZsDefZoneChangeNotify: NO

t11ZsActivateNotify: NO

Note: The Zone Mib parameters are for restricted usage only.

To restore the systemGroup configuration to default values:

switch:admin> snmpconfig --default systemGroup

*****

This command will reset the agent's system group

configuration back to factory default

*****

sysDescr = Fibre Channel Switch

sysLocation = End User Premise

sysContact = Field Support

authTraps = 0 (OFF)

*****

Are you sure? (yes, y, no, n): [no] y

To set the security level:

switch:admin> snmpconfig --set seclevel

Select SNMP Security Level

(0 = No security, 1 = Authentication only,

2 = Authentication and Privacy, 3 = No Access): (0..3) [0] 1

Select SNMP SET Security Level

(0 = No security, 1 = Authentication only,

2 = Authentication and Privacy, 3 = No Access): (1..3) [1]

To display the SNMP3 configuration with informs disabled (in the example, the Engine ID in the user1
entry corresponds to the engine ID of the trap manager in Trap Entry 2: 10.103.5.105):

switch:admin> snmpconfig --show snmpv3

SNMP Informs = 1 (ON)

SNMPv3 USM configuration:

User 1 (rw): snmpadmin1