Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual

Page 199

Advertising
background image

Fabric OS Command Reference

169

53-1003131-01

configureChassis

2

1

Sets the CS_CTL to VC mapping to support three CS_CTL values: 1 (low
priority), 2 (medium priority), and 3 (high priority). Each CS_CTL value can
map to more than one VC depending on the underlying support from ASIC.
This is the auto mode. For more information about CS_CTL-based frame
prioritization, refer to the Fabric OS Administrator's Guide.

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

None

EXAMPLES

To enable signature validation for downloading firmware:

switch:admin> configurechassis

Configure...

cfgload attributes (yes, y, no, n): [no] y

Enforce secure config Upload/Download (yes, y, no, n): [no]

Enforce signature validation for firmware (yes, y, no, n): [no]y

Add Suffix to the uploaded file name (yes, y, no, n): [no]

Do you want to enable auto firmwaresync (yes, y, no, n): [no]

Custom attributes (yes, y, no, n): [no]

system attributes (yes, y, no, n): [no]

fos attributes (yes, y, no, n): [no]

To add a suffix to the uploaded file name:

switch:admin> configurechassis

Configure...

cfgload attributes (yes, y, no, n): [no] y

Enforce secure config Upload/Download (yes, y, no, n): [no]

Enforce signature validation for firmware (yes, y, no, n): [no]

Add Suffix to the uploaded file name (yes, y, no, n): [no] y

Do you want to enable auto firmwaresync (yes, y, no, n): [no]

Custom attributes (yes, y, no, n): [no]

system attributes (yes, y, no, n): [no]

fos attributes (yes, y, no, n): [no]

Advertising