Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual

Page 948

Advertising
background image

918

Fabric OS Command Reference

53-1003131-01

portShow

2

Keepalive Timeout: 10000

Path MTU Disc: 0

VLAN ID: 300

L2CoS: F: 7 H: 5 M: 3 L: 1

DSCP: F: 0 H: 0 M: 0 L: 0

Flags: 0x00000000

To display additional performance parameters for a circuit:

switch:admin> portshow fcipcircuit 1/12 0 --perf

-------------------------------------------

Tunnel ID: 1/12

Tunnel Description:

Admin Status: Enabled

Oper Status: Up

Compression: Off

Fastwrite: Off

Tape Acceleration: Off

TPerf Option: Off

IPSec: Disabled

QoS Percentages: High 50%, Med 30%, Low 20%

Remote WWN: Not Configured

Local WWN: 10:00:00:05:1e:52:fe:00

Peer WWN: 10:00:00:05:1e:39:a4:76

Circuit Count: 2

Flags: 0x00000000

FICON: Off

Oper Status: Up

Flow Ctrl State: Off

Connected Count: 1

Tunnel Duration: 3 days, 19 hours, 54 minutes, 5 seconds

Compression Statistics:

0 Uncompressed Bytes

0 Compressed Bytes

1.00 : 1 Compression Ratio

Performance Statistics: Overall Throughput

31073824 Output Bytes

16 Bps 30s Avg, 93 Bps Lifetime Avg

70932 Output Packets

0 pkt/s 30s Avg, 0 pkt/s Lifetime Avg

69170308 Input Bytes

85 Bps 30s Avg, 209 Bps Lifetime Avg

92393 Input Packets

0 pkt/s 30s Avg, 0 pkt/s Lifetime Avg

TCP Stats:

1450493536 Output Bytes

16107875 Output Packets

844887492 Input Bytes

16117320 Input Packets

Retransmits: 0

Round Trip Time: 0 ms

Out Of Order: 0

Slow Starts: 0