7B.35

Model 8042, 10042, 10054 Legacy

Rev. 10/03

Engine: Cummins QSB4.5T

12. Use a small, flat knife blade (19), inserted next to the

cap (18), so that the cap pops out of the protective
cover.

13. Label the blue wire (20) from the starter solenoid

terminal. Use a small phillips screwdriver to loosen
the screw far enough to allow the blue wire to be
removed from the terminal.

14. Remove the locknuts and washers (16) securing the

coldstart grid heater (17) to the frame studs and
place it, out of the way, on the engine.

15. Label and disconnect the back-up alarm harness

connector (18) from the back-up alarm (19). Refer to
Section 9.11.2, “Back-up Alarm.”

16. Label and disconnect the engine coolant temperature

switch lead (20). Refer to Section 9.14.12, “Engine
Coolant High Temperature Sender.”

17. Label and remove oil pressure switch lead (21).

18. Label and remove the diagnostic system ground

wire (22) at the buss bar (23).

MH49102

16

17

MH5250

18

19

MH5220

20

MH5210

21

22

23