SkyTrak 8042 Service Manual User Manual

Page 444

Advertising
background image

8.29

Model 8042, 10042, 10054 Legacy

Rev. 10/03

Hydraulic System

NOTE:

When checking pressures in
circuits, refer to Section 8.7,
“Hydraulic System Testing,” f
or
correct pressure readings.

Before troubleshooting any hydraulic circuit, ALWAYS begin by checking the following:

1. Hydraulic oil level in the reservoir
2. All hoses, tubes, fittings for leaks, kinks, interference, etc.
3. Air in the lines

Not

OK

Not

OK

With the boom below 40°, if

the frame sway cylinder will

not sway left, drifts or reacts

slowly, check cable

connections at the main

control valve.

Replace check valves on

frame sway cylinder.

If OK

If OK

Not

OK

Repair/replace cable

connections. Ensure frame

sway section of main control

valve is functioning.

Check frame sway

cylinder packing.

Repair/replace frame

sway cylinder.

Refer to Section 10.12, “Stabil-TRAK™ Hydraulic Circuit
Operation and Troubleshooting,”

for further information on

troubleshooting the frame sway and stabilizer circuits.

NOTE:

Refer to Section 2.5.4, “Performance
Specifications,” f
or approximate cylinder cycle
times. The operation of the system function
should approximate the times listed.

Check the pilot-operated check
valves on frame sway cylinder.

Advertising
This manual is related to the following products: