Electrical system – SkyTrak 8042 Service Manual User Manual

Page 706

Advertising
background image

9.115

Model 8042, 10042, 10054 Legacy

Rev. 10/03

Electrical System

Check 40 amp main fuse and

7.5 amp transmission fuse.

Check that transmission gear

select lever is in the

NEUTRAL (N) position.

Engine will not crank or

starter solenoid does

not engage.

Check that parking brake

switch is ENGAGED.

Check battery for proper

charge and that connections

are clean and tight.

With ignition switch in START

position, check starter

solenoid terminal, wire

[106] (BLU/ORG) connection

for battery voltage.

Replace starter.

Check for battery voltage at

starter positive (+) battery

post (RED cable). Check

negative (-) cables for proper

ground and that they are

clean and tight.

Continued on Page 9.117

Clean, tighten and recheck.

Before troubleshooting any
electrical circuit, ALWAYS
begin by checking the
following:

1. All connections relating to

circuit are clean and tight.

2. On 10042 or 10054, if the

vehicle is starting hard,
make sure that both
outrigger switches are in
the neutral (center)
position.

If OK

Not

OK

If OK

If OK

If OK

If OK

If OK

SN 13198 through 16782 w/o Lighting Package. See pages 9.38, 9.39, 9.62, 9.63, 9.84 or 9.85.

§

SN 13198 through 16782 w/Lighting Package and SN 16783 through 18990. See pages 9.40, 9.41, 9.64, 9.65, 9.86 or 9.87.

These wires are not part of a wire harness. Refer to the appropriate Parts Manual for part number information.