Electrical system – SkyTrak 8042 Service Manual User Manual

Page 732

Advertising
background image

9.141

Model 8042, 10042, 10054 Legacy

Rev. 10/03

Electrical System

Check for battery voltage at

blower switch connector,

Pin 2, wire [2] (RED/WHT).

Heater fan does not

operate.

Repair/replace

heater harness.

Check for battery voltage at

blower switch connector; Pin

1, wire [1] (YEL) with switch

set to LOW speed; Pin 4,

wire [4] (RED) with switch set

to MEDIUM speed; and Pin 3,

wire [3] (ORG) with switch set

to HIGH speed.

Replace blower switch.

Not

OK

If OK

Before troubleshooting any
electrical circuit, ALWAYS
begin by checking the
following:

1. All connections relating

to circuit are clean and
tight.

Check 15-amp heater fuse.

Replace fuse.

Not

OK

If OK

Not

OK

Check for battery voltage at

fuse block female connector

wire [52] (ORG).

Repair/replace cab harness.

Not

OK

If OK

Check for battery voltage at

blower connector; Pin 1, wire

[1] (YEL) with switch set to

LOW speed; Pin 4, wire [4]

(RED) with switch set to

MEDIUM speed; and Pin 3,

wire [3] (ORG) with switch set

to HIGH speed.

If OK

Not

OK

Repair/replace

heater harness.

If OK

Check for proper ground at

blower motor.

If OK

Not

OK

Clean, tighten and recheck.

Replace blower motor.

Advertising