Stabil-TRAK™ System and Boom Interlock System

10.54

Model 8042, 10042, 10054 Legacy

Rev. 10/03

10.13.4

Hydraulic Circuit Operation -
Outrigger Interlock Mode

Operation:

When the outriggers are lowered onto firm terrain,
pressure within the outrigger cylinders close the outrigger
pressure switches (1 and 2), energizing the boom extend
lockout solenoid valve (3).

As the boom extends past the boom extend switch, the
switch opens. The boom extend lockout solenoid
valve (3), remains energized by the circuit provided by
the outrigger pressure switches.

Pressurized oil flows to the base of the pilot-operated
valve (4), opening the valve and allowing oil to flow to the
extend/retract cylinder (5).

10.13.5

Hydraulic Troubleshooting - Outrigger Interlock Mode

Not

OK

Not

OK

Boom will not extend to its full limits.

Conditions:

• Both outriggers lowered onto

firm terrain.

Note: When the outrigger
interlock mode is engaged, the
following systems are
automatically activated:

• Stabil-TRAK™ system is in the

LOCKED MODE. (Refer to
Section 10.4, “Stabil-TRAK™
Operation,”
for more
information.)

• Transmission has been

DECLUTCHED.

• Park brake ENGAGED.

• Outrigger RAISE function has

been DISABLED. However, the
LOWER function is still active,
to allow for any changes in
outrigger footing.

Check solenoid coil from the boom
lockout valve for correct resistance

(7-9 ohms).

Remove solenoid cartridge from boom

lockout valve and inspect

for debris or damage. Refer to Section

8.12.9, “Extend Lockout Valve (10054).”

Replace solenoid.

Clean passages or replace

cartridge.

If OK

If OK

If OK

Not

OK

Replace check valve(s).

Inspect check valves on extend/retract

cylinder. Refer to Section 8.13.6,

“Extend/Retract Cylinder.”

Not

OK

Check outrigger pressure switches for

proper operation. Refer to Section

9.14.5, “Outrigger Switches (10042/

10054 Only).”

Replace switch(es).

If OK

Not

OK

Check electrical wiring.

Refer to Section 10.9, “Stabil-

TRAK™ Boom Interlock

Electrical Circuit Operation

and Troubleshooting

(10054, 13198-17984),” or

Section 10.10, “Stabil-

TRAK™ Boom Interlock

Electrical Circuit Operation

and Troubleshooting

(10054, 17985-19987 and

0160002332 & After),”