background image

8.161

Model 8042, 10042, 10054 Legacy

Rev. 10/03

Hydraulic System

For Early Production

b. Swing Carriage Cylinder Disassembly

Note: An additional o-ring may be included at the base
of the cylinder rod. This additional o-ring may be
discarded, as it served only in a temporarily protective
role.

1. Clean the swing carriage cylinder (1) with a suitable

cleaner to remove dirt, debris, grease, etc.

IMPORTANT: Avoid using excess force when clamping
the cylinder in a vise. Apply only enough force to hold the
cylinder securely. Excessive force can damage the cylinder.

2. Secure the swing carriage cylinder in a soft-jawed

vise or other acceptable holding equipment if possible.

3. Slowly remove the 3000 psi (207 bar) counterbalance

cartridge (2) and the 2000 psi (138 bar) direct-acting
relief valve (3) from the swing carriage cylinder.

4. If the self-aligning bearing (4) requires replacement,

support the rod (5) in a soft-jawed vise or other
suitable holding device. Carefully press the bearing
out of the rod eyelet.

5. Extend the rod (5) to access the cylinder base.

IMPORTANT: Protect the finish on the rod at all times.
Damage to the surface of the rod can cause seal failure.

6. Using a pin spanner wrench, unscrew the head

gland (6) from the cylinder tube (7). The head gland
was originally torqued to 250-300 lb-ft (339-407
Nm), so a considerable amount of force is required.
Carefully slide the head gland down along the rod
toward the eyelet, away from the cylinder tube (7).

IMPORTANT: When sliding the rod and piston assembly
into the tube, prevent the threaded end of the tube from
damaging the piston (8)
. Keep the rod centered within the
tube to help prevent binding.

7. Carefully pull the rod (5) with all attachments straight

out of the tube (7).

8. Fasten the rod end in a soft-jawed vise, and put a

padded support below and near the threaded end of
the rod to help prevent damage to the rod.

MT1911

1

2

3

4

5

6

7

8

WARNING:

Significant pressure may be

trapped inside the cylinder. Exercise caution
when removing a counterbalance valve or a
pilot-operated check valve from a cylinder.
Escaping hydraulic fluid under pressure can
penetrate the skin, causing death or serious injury.