8.31

Model 8042, 10042, 10054 Legacy

Rev. 10/03

Hydraulic System

NOTE:

When checking pressures in
circuits, refer to Section 8.7,
“Hydraulic System Testing,” f
or
correct pressure readings.

Before troubleshooting any hydraulic circuit, ALWAYS begin by checking the following:

1. Hydraulic oil level in the reservoir
2. All hoses, tubes, fittings for leaks, kinks, interference, etc.
3. Air in the lines

Not

OK

Not

OK

Replace check valves on

frame sway cylinder.

If OK

If OK

Not

OK

Check the pilot-operated check
valves on frame sway cylinder.

Repair/replace cable

connections. Ensure frame

sway section of main control

valve is functioning.

Check frame sway

cylinder packing.

Repair/replace frame

sway cylinder.

Refer to Section 10.12, “Stabil-TRAK™ Hydraulic Circuit
Operation and Troubleshooting,” f
or further information on
troubleshooting the frame sway and stabilizer circuits.

With the boom below 40°, if

the frame sway cylinder will

not sway right, drifts or

reacts slowly, check cable

connections at the main

control valve.

NOTE:

Refer to Section 2.5.4, “Performance
Specifications,” f
or approximate cylinder cycle
times. The operation of the system function
should approximate the times listed.