Hydraulic system – SkyTrak 8042 Service Manual User Manual

Page 458

Advertising
background image

8.43

Model 8042, 10042, 10054 Legacy

Rev. 10/03

Hydraulic System

Not

OK

Not

OK

If the outriggers do not go

up, check the left and right

outrigger switches.

Check pump flow.

Not

OK

Check outrigger shuttle valve

on main control valve.

If OK

Not

OK

Check the left and right

outrigger cylinders for

packing leaks.

If OK

Not

OK

Check the solenoid valves on

the outrigger valve.

If OK

Not

OK

Not

OK

If OK

Check the counterbalance valve

in each outrigger cylinder.

Check the spools in the

solenoid valves.

If OK

If OK

NOTE:

When checking pressures in
circuits, refer to Section 8.7,
“Hydraulic System Testing,” f
or
correct pressure readings.

Before troubleshooting any
hydraulic circuit, ALWAYS
begin by checking the
following:

1. Hydraulic oil level in the

reservoir

2. All hoses, tubes, fittings

for leaks, kinks,
interference, etc.

3. Air in the lines

NOTE:

Refer to Section 2.5.4,
“Performance Specifications,”
for
approximate cylinder cycle
times. The operation of the
system function should
approximate the times listed.

Replace shuttle valve.

Repair/replace pump.

Refer to Section 9.14.5,

“Outrigger Switches (10042/

10054 Only).”

Replace solenoid valves.

Replace counterbalance valve(s).

Repair/replace outrigger

cylinder(s).

Refer to Section 9.7.42, “10042

Outrigger Circuit and

Troubleshooting,” and Section

9.7.43, “10054 Outrigger Circuit

and Troubleshooting.”

Advertising