The SM_PLCopen.lib library

POUs for the motion control of individual axes

130

L

DMS 5.2 EN 03/2011 TD17

6.2.18

MC_MoveSuperImposed

Where applicable, this program organisation unit from SM_PLCopen.lib executes a motion

in addition to the currently active motion, which moves the axis across a defined distance.

The specified velocity, acceleration and deceleration values must be regarded as relative

values, i.e. they are independent of the underlying motion.
The program organisation unit that was originally active will not be interrupted by

MC_MoveSuperImposed. If it is interrupted by another program organisation unit whilst

MC_MoveSuperImposed is active, the MC_MoveSuperImposed motion will be aborted.
Please note that MC_MoveSuperImposed must be called after the program organisation

unit generating the underlying motion.

Input/output (VAR_IN_OUT)
Axis : AXIS_REF
The structure that is filled with axis data in the Drive Interface (SM_DriveBasic.lib) is shown

here.

Inputs (VAR_IN)
Execute : BOOL (default: FALSE)
The program organisation unit is activated on a rising edge.
Distance : REAL
Relative distance for the motion (technical unit [u])
VelocityDiff : REAL
Maximum velocity difference in relation to the current motion that does not necessarily

have to be reached [u/s]
Acceleration : REAL
Desired acceleration [u/s²]
Deceleration : REAL
Desired deceleration [u/s²]