The L_SMC_DriveUtil.lib library (Lenze specifications)

Function blocks for EtherCAT

Outputs (VAR_OUT)
bDone : BOOL
TRUE indicates that the selection has been acknowledged.
bError : BOOL
TRUE indicates that an error has occurred in the function block.
nErrorID SMC_Error: INT
Error number

Error messages
The following error messages are stored:

 Example 1: The PLC wants to set the torque limit value positively to 50 %.

The drive sets the positive torque limit value to 50 % of the rated torque; the negative

torque limit value that is valid within the drive is not changed.

 Example 2: The PLC wants to set both torque limit values to 100 %.

The drive sets both torque limit values to 100 % of the rated torque.

Error message

Description

ERROR_NO_LENZE_AXIS_REF: INT := 16#200

Function is not supported by this drive.

ERROR_TORQUE_LIMIT_NOT_VALID: INT := 16#210

Value range exceeded.

Only torque limit values from 0 … 200 % are permissible.

SetTorqueLimitPos = TRUE
TorqueLimitPos_Value: 50.0
SetTorqueLimitNeg = FALSE
TorqueLimitNeg_Value = xxx
Execute = True

SetTorqueLimitPos = TRUE
TorqueLimitPos_Value: 100.0
SetTorqueLimitNeg = TRUE
TorqueLimitNeg_Value = 100.0
Execute = True