DMS 5.2 EN 03/2011 TD17

L

19

L-force | PLC Designer - SoftMotion

The SoftMotion drive interface

Control configuration for SoftMotion

3.1.1

BusInterface

Here usually only the communication driver is selected.

 BusInterface_CAN:

 BusInterface_EtherCAT:

 BusInterface_Dummy:

Parameters of the PLC configuration

Note!

The configuration of the axis group is cancelled if
• the control system has detected an error on a drive;
• a drive is not available physically;
• a module parameter value beyond the value range specified for this purpose

has been set for a drive in the Control configuration under the Service Data

Objects tab.

This can be checked with the AXIS_REF-Strukturvariable bCommunication

structure variable:
bCommunication = TRUE: No error, drive responds
bCommunication = FALSE: An error has occurred
Do not rename the axis groups and drives added to the control configuration

after the import of a configuration file (XML). If you carry out another import, the

names will overwritten.

Parameter

Description

wParam1 Not

used

wParam2

Not used

dwParam1

Not used

dwParam2

Not used