3 diagnostic function blocks, 1 smc_axisdiagnosticlog, Diagnostic function blocks – Lenze PLC Designer PLC-Designer (R2-x) SoftMotion User Manual

Page 255: Smc_axisdiagnosticlog, L-force | plc designer - softmotion

Advertising
background image

L-force | PLC Designer - SoftMotion

The SM_FileFBs.lib library

Diagnostic function blocks

255

L

DMS 5.2 EN 03/2011 TD17

11.3

Diagnostic function blocks

11.3.1

SMC_AxisDiagnosticLog

This program organisation unit can be used to write selected axis values to a file cyclically.

The resulting file is ideal for diagnostic use.
As it usually takes quite some time to write data to a data medium, this program

organisation unit stores the collected data in a 5 KB buffer and the data is not written until

the WriteToFile POU action is called. This call should, therefore, be moved to a slower

(around 50 ms) task of lower priority to ensure that the actual motion task is not

obstructed and that the drive behaviour is not disturbed. If the buffer overflows, the

program organisation unit will generate an error.

Inputs/outputs (VAR_IN_OUT)
Axis: AXIS_REF;
Axis to be watched

Inputs (VAR_IN)
bExecute: BOOL
The program organisation unit starts on a rising edge. If a file of the same name already

exists, it will be overwritten.
bCloseFile: BOOL
The program organisation unit closes the file as soon as this input assumes the value TRUE.
sFileName: STRING(80)
File path and name
bSetPosition, bActPosition, bSetVelocity, bActVelocity, bSetAcceleration,

bActAcceleration: BOOL
These inputs determine whether the associated axis values will be saved to the file or not.
bySeparatorChar: BYTE (default: TAB)
ASCII code of the character to be written between two values of the same data item