L-force | PLC Designer - SoftMotion

The SM_PLCopen.lib library

POUs for the motion control of individual axes

Error number
Example:
The following figure shows two examples of the combination of two MoveVelocity

Function Blocks:

1. The left part of timing diagram illustrates the case if the Second Function Block is called

after the First one is completed. If First reaches the commanded velocity 3000 then the

output First.InVelocity AND the signal Next cause the Second FB to move to the velocity

2000.

2. The right part of the timing diagram illustrates the case if the Second move Function

Blocks starts the execution while the First FB is not yet InVelocity. The following

sequence is shown: The First motion is started again by Go at the input First.Execute.

While the First FB is still accelerating to reach the velocity 3000 the First FB will be

interrupted and aborted because the Test signal starts the Run of the Second FB. Now

the Second FB runs and decelerates the velocity to 2000.