L-force | PLC Designer - SoftMotion

The SoftMotion drive interface

Variables of the AXIS_REF structure

56

L

DMS 5.2 EN 03/2011 TD17

3.4

Variables of the AXIS_REF structure

For each drive created in the »PLC Designer« control configuration a variable of the

AXIS_REF structure is created during the compilation process (defined in the

SM_DriveBasic.lib, see chapter

[3.2]

( 26)

). This structure provides the interface between

the application and the drive interface. It serves to exchange both cyclic and acyclic data.
Most variables of the structure have no importance for the user, but are used internally by

the system. The user should always use function blocks and should never directly access

the structure, at least not in the writing mode.

No.

Name

Data type

Init value

Description

1000

nAxisState

INT

Standstill

Axis status:

0: power_off

1: errorstop

2: stopping

3: standstill

4: discrete_motion

5: continuous_motion

6: synchronized_motion

7: homing

1001

wControlType

WORD

PLC config*

Digit showing the components of

the structure which are

transmitted and received

cyclically.

0: defined by param 1002 ... 1008

1: SetTorque

2: SetVelocity,ActVelocity

3: SetVelocity,ActPosition

4: SetPosition,ActPosition

5: SetVelocity,SetPosition,

ActVelocity,ActPosition

6: SetVelocity

1002

1003

1004

wCyclicDataS1

wCyclicDataS2

wCyclicDataS3

WORD

PLC-Config* or init-FB

of

<BusInterfaceName>

Drive.lib

Number of the 3S parameters

that are to be transmitted per

cycle

1006

1007

1008

wCyclicDataR1

wCyclicDataR2

wCyclicDataR3

WORD

PLC-Config* or init-FB

of

<BusInterfaceName>

Drive.lib

Parameter numbers of the 3S

parameters that are to be

received per cycle

1010

bRegulatorOn

BOOL

FALSE

Connect/switch off controller

(power)

1011

bDriveStart

BOOL

FALSE

Activate/deactivate brake

1012

bCommunication

BOOL

FALSE

TRUE: drive responds

1013

wCommunication

State

WORD

0

Internal use

1015

bRegulatorRealState BOOL

FALSE

Status of the controller

1016

bDriveStartRealState BOOL

FALSE

Status of the brake

1020

wAxisGroupId

WORD

PLC config*

Index of the axis group in the

configuration

1021

wDriveId

WORD

PLC config*

Node number of the drive on the

fieldbus

1022

iOwner

INT

0

ID number of the current owner

(FB)

1023

iNoOwner

INT

0

Number of the previous and

current owners