The L_SMC_DriveUtil.lib library (Lenze specifications)

Function blocks for EtherCAT

264

L

DMS 5.2 EN 03/2011 TD17

12.2.2

L_SMC_AbortTrigger

Inputs (VAR_INPUT)
Execute : BOOL
By setting a new positive edge, all outputs of the block are reset to the initial values.
Axis : AXIS_REF
Selection of the drive
TriggerInput: L_SMC_TRIGGER_REF
Structure for configuring the measurement

Outputs (VAR_OUTPUT)
Done : BOOL
Function block L_SMC_TouchProbe was aborted.
Error : BOOL
Error identification: An error during the command to be executed has occurred.
ErrorId: INT
Error number

Error messages
The following error messages are stored:

Note

This block currently only supports EtherCAT axes.

Error number

[hex]

Description

0x0001

Error in the command to be executed of the block:

• Input data do not correspond to the activated TP command to be executed on this channel.

If no request is active on the TP channel, no error message is generated.

• TouchProbeSelect > 1 for ECSxM

• TouchProbeSelect > 2 for Servo Drive 9400