The SoftMotion drive interface

SM_DriveBasic.lib and automatic code generation

46

L

DMS 5.2 EN 03/2011 TD17

Dead time compensation and filtering for a master/slave connection
The actual positions read-in by an encoder have a certain runtime for control. The setpoints

calculated in the control have a certain runtime as well until they get effective in the drive.

The SMC_Encoder POU offers the possibility to compensate these runtimes by an

extrapolation (advance calculation) of the read-in encoder values. Here, it is required to

filter the position values before extrapolation. A corresponding filter function is also

included in the POU.
In the SMC_Encoder_REF data structure, the dead time compensation and filtering of the

input signal can be activated by writing the elements fDeadTimeCycle and usiFilterDepth.
fDeadTimeCycle: Number of PLC cycles via which the extrapolation takes place.
Depending on the fieldbus, encoder and drive type used, a value between 5.0 and 7.0 cycles

must be entered. The exact value must be detected for the runtime at the machine.
usiFilterDepth: Number of position values via which filtering takes place.
Here, the setting also depends on the quality or accuracy of the read-in actual position and

thus on the encoder used. As starting value, 5 position values are sensible here and an

optimisation is also required. The max. filter depth is 16 position values.

Note!

A too low filter depth causes a disturbed behaviour of the controlled slave axis.

A too high filter depth causes a strong smoothing of the speed variations of the

encoder.