Fixed s curve, Adjustable s curve, Language – Rockwell Automation 1336F PLUS II User Manual - Firmware 1.xxx-6.xxx User Manual

Page 103: Flying start en, Feature select

Advertising
background image

Programming

6–21

Feature Select

Case 2

Accel Time

1 or 2

Decel Time

1 or 2

Speed

Time

S Curve Time + Accel Time 1 or 2

Accel Time

1 or 2

S Curve Time + Decel Time 1 or 2

Decel Time

1 or 2

Speed

Case 1

Time

Fixed S Curve

Accel Time = 2 x [Accel Time 1 or 2]
Decel Time = 2 x [Decel Time 1 or 2]

Adjustable S Curve

Case 1

(see adjacent diagram)

[S Curve Time] < [Accel Time 1 or 2], and
[S Curve Time] < [Decel Time 1 or 2],
then
Accel Time = [Accel Time 1 or 2] + [S Curve Time], and
Decel Time = [Decel Time 1 or 2] + [S Curve Time]

Case 2

[S Curve Time]

≥ [Accel Time 1 or 2], and

[S Curve Time]

≥ [Decel Time 1 or 2],

then
Accel Time = 2 x [Accel Time 1 or 2], and
Decel Time = 2 x [Decel Time 1 or 2]

Note: If [S Curve Time]

≥ programmed accel/decel times

any further increase in [S Curve Time] will have no effect
on the total accel/decel times.

[Language]

This parameter selects the language for the HIM display.

To return to the default language (English) after an alter-
nate language has been inadvertently selected:
a) Cycle drive power
b) Press the Increment key 5 times
c) Press Enter
d) Press the Increment key 2 times
e) Press Enter

Parameter Number

47

Parameter Type

Read and Write

Factory Default

“English”

Units

Display Drive

“English” 0

“FRANCAIS” 1

“ESPANOL” 2

“Italiano” 3

“Deutsch” 4

“Japanese” 5

Not available with v5.001 & later

“Portuguese” 6
“Nederlands” 7

[Flying Start En]

This value enables the flying start function and chooses
the method to be used. The drive will first search from the
direction it was last running.

Firmware 5.001 & later – When restarting high inertia
loads, use the longer speed searches to match load speed.
This may minimize Overvolatge and Overcurrent faults.

Parameter Number

155

Parameter Type

Read and Write

Factory Default

“Disabled”

Units

Display Drive

“Disabled” 0

“Speed Search” 1

Freq. sweep -see [FStart For./Rev.]

“Use Encoder” 2

Requires feedback encoder

B Frame & Up drives Only

“Track Volts” 3

Read back EMF from sync. pm motor

Firmware 5.001 & later

“Speed Srch 10s” 4

Frequency sweep takes 10 seconds

Firmware 5.001 & later

“Speed Srch 20s” 5

Frequency sweep takes 20 seconds

Firmware 5.001 & later

“Speed Srch 40s” 6

Frequency sweep takes 40 seconds

ATTENTION: The “Speed Search” selection should not be used with
synchronous or permanent magnet motors. Motors may be demagnetized
during braking.

!

Advertising