Information and Precautions

General Precautions

Conventions Used in this
Manual

To help differentiate parameter names and display text from other text
the following conventions will be used:

Parameter Names will appear in [brackets]

Display Text will appear in “quotes”

Catalog Number Explanation

The diagram on the following page describes the 1336

PLUS

II

catalog numbering scheme.

!

ATTENTION: This drive contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing
or repairing this assembly. Component damage may result
if ESD control procedures are not followed. If you are not
familiar with static control procedures, reference A-B
publication 8000-4.5.2, “Guarding Against Electrostatic
Damage” or any other applicable ESD protection
handbook.

!

ATTENTION: An incorrectly applied or installed drive
can result in component damage or a reduction in product
life. Wiring or application errors, such as, undersizing the
motor, incorrect or inadequate AC supply, or excessive
ambient temperatures may result in malfunction of the
system.

!

ATTENTION: Only personnel familiar with the 1336

PLUS

II

Adjustable Frequency AC Drive and associated

machinery should plan or implement the installation, start-
up and subsequent maintenance of the system. Failure to
comply may result in personal injury and/or equipment
damage.

!

ATTENTION: To avoid a hazard of electric shock, verify
that the voltage on the bus capacitors has discharged before
performing any work on the drive. Measure the DC bus
voltage at the + & - terminals of TB1. The voltage must be
0.0V DC.