Analog i/o, Analog i/o –32, The 1336 – Rockwell Automation 1336F PLUS II User Manual - Firmware 1.xxx-6.xxx User Manual

Page 42: Plus

Advertising
background image

2–32

Installation/Wiring

Analog I/O

The 1336

PLUS

II

analog I/O configuration provides a standard set of

inputs and outputs with the capability to install up to 2 option boards,
thus replacing the standard I/O with a variety of options. All connec-
tions are performed at TB2. Installing an option board in the slot A or
B location will change the function of those terminals on TB2 from
standard. Only one option board can be installed in each slot.

Figure

2.6

shows the standard and optional I/O configurations.

Figure 2.6
Analog I/O – TB2

Analog 0-10V, 4-20 mA and Pulse I/O Examples

1

TE

TE

Signal

Common

Only Present

on B Frame

& Up Drives

2

3

4

5

6

9

8

7

Isolated
Input 0 (–)
10V or 20mA

Isolated
Input 0 (–)

±10V, ±20mA

Isolated
Input 0 (–)

±10V, ±20mA

Isolated
Input 0 (+)
10V or 20mA

Isolated
Input 0 (+)

±10V, ±20mA

Isolated
Input 0 (+)

±10V, ±20mA

LA2

LA6

LA7

Analog I/O Option Slot A

Analog I/O Option Slot B

Isolated
Input 1 (+)
10V or 20mA

Thermistor
Isolated
Input (+)

Isolated
Input 1 (+)
10V or 20mA

Isolated
Input 1 (–)
10V or 20mA

Thermistor
Isolated
Input (–)

Isolated
Input 1 (–)
10V or 20mA

Pot.
Reference
+5V

1, 3

Single-Ended
Input 0
Pot., 10V or 20mA

Single-Ended
Input 1
Pot., 10V or 20mA

Signal
Common

S

i

g
n
a

l

C

o

m
m

o
n

Std.

LA1

LA3

LA4

LA5

Std.

or (select 1)

or (select 1)

Single-Ended
Input 2

2

Pot., 10V or 20mA

Isolated
Output 0 (+)
10V or 20mA

Isolated
Input 2 (+)
10V or 20mA

Single-Ended
Output 0
10V or 20mA

Single-Ended
Output 0
10V or 20mA

Isolated
Output 0 (–)
10V or 20mA

Isolated
Input 2 (–)
10V or 20mA

Non-Isolated
250 kHz
Pulse Output

Single-Ended
Output 1
20mA Only

Isolated
Output 1 (+)
10V or 20mA

Isolated
Output 1 (+)
10V or 20mA

Isolated
250 kHz
Pulse In (+)

0-20mA
Output
Return

Isolated
Output 1 (–)
10V or 20mA

Isolated
Output 1 (–)
10V or 20mA

Isolated
250 kHz
Pulse In (–)

Signal
Common

Single Ended
Output 1
0-10V Only

Single Ended
Output 0
0-10V Only

Single-Ended
Input 2
Pot., 10V or 20mA

1

If an Option Board is installed in Slot A, the +5V pot. reference will not be
available. If a 5V source is required, it must be user supplied.

2

Standard Analog Input 2 is maintained at this terminal – configure with J11.

3

10k Ohm potentiometer required.

Standard I/O

Optional I/O

Standard Analog

Refer to page

2–36

for Analog I/O
specifications

Pulse with
LA5 Option

Analog I/O
with LA2/LA3
Options

0-10V

Standard Analog Input 2

(Non-Isolated)

Standard Analog Output 0

(0-10V Non-Isolated)

5

6

9

8

7

+

+

Jumper J11 Set to "0-10V"

5

6

7

Isolated Pulse Train Input

to LA5 Option Board

Pulse Train Output from LA5

Option Board (Non-Isolated)

Common

+

9

8

Pulse

Source

Isolated Input to

LA2 Option Board

Isolated Output from

LA3 Option Board

+

2

1

+

9

8

Advertising