Masks, Direction mask, Start mask – Rockwell Automation 1336F PLUS II User Manual - Firmware 1.xxx-6.xxx User Manual

Page 125: Jog mask, Reference mask, Accel mask

Advertising
background image

Programming

6–43

Masks

This group of parameters contains binary masks for all control functions. The masks control
which adapters can issue control commands.

Each mask contains a bit for each adapter. Individual bits
can be set to “Zero” to lockout control by an adapter or set
to “1” to permit an adapter to have control.

A Status description (bit ENUM) is displayed on line 1 (ex-
cept Series A HIMs below version 3.0).

[Direction Mask]

This parameter controls which adapters can issue forward/
reverse commands.

If [Freq Select 1] or [Freq Select 2] is set to “Analog In 0”
and an Analog Option Board with bipolar input (LA6, LA7)
is installed, that input (designated “Analog In 0”) will have
exclusive ownership of direction. Bit 7 of [Direction Mask]
must not be set to “0” and no other device can have claimed
ownership of direction (i.e. TB3 - Run Reverse). If either
condition is true, a fault will be issued.

Parameter Number

94

Parameter Type

Read and Write

Factory Default

01111110

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Start Mask]

This parameter controls which adapters can issue start
commands.

Parameter Number

95

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Jog Mask]

This parameter controls which adapters can issue jog
commands.

Parameter Number

96

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Reference Mask]

This parameter controls which adapters can select an al-
ternate reference; [Frequency Sel 1], [Frequency Sel 2] or
preset speeds.

Parameter Number

97

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

[Accel Mask]

This parameter controls which adapters can select [Accel
Time 1] and [Accel Time 2].

Parameter Number

98

Parameter Type

Read and Write

Factory Default

01111111

Units

Display Drive

“0” 0

Deny Control

“1” 1

Permit Control

TB3
Adapter 1
Adapter 2
Adapter 3
Adapter 4
Adapter 5
Adapter 6
LAx

Bit 7 Bit 6

Bit 5 Bit 4 Bit 3

Bit 2 Bit 1 Bit 0

Mask