Power mode, Output pulses, Current angle – Rockwell Automation 1336F PLUS II User Manual - Firmware 1.xxx-6.xxx User Manual

Page 121: Heatsink temp, Set defaults, Diagnostics

Advertising
background image

Programming

6–39

Diagnostics

[Power Mode]

This parameter displays the power mode.

Parameter Number

142

Parameter Type

Read Only

Factory Default

None

Units

Display Drive

“1” 1

Power up sequence in progress

“2” 2

Precharge in progress

“3” 3

Bus voltage being stored in memory

“4” 4

Ready for run command after
power up

“5” 5

Power stage diagnostics running

“6” 6

Line loss detection occurred

“7” 7

Ready for run command after stop

“8” 8

Drive running

“9” 9

Motor flux decay delay

“10” 10 DC braking in progress
“11” 11 Drive fault occurred
“12” 12 Flying start search enabled
“13” 13 Deceleration in progress
“14” 14 SCR wake mode
“15” 15 SCR check mode
“16” 16 SCR wait mode

[Output Pulses]

This parameter displays the number of output cycles for
the PWM waveform. The count rolls over at 65535.

Parameter Number

67

Parameter Type

Read Only

Display Units / Drive Units

1 Pulse / Pulses

Factory Default

None

Minimum Value

0

Maximum Value

65535

[Current Angle]

This parameter displays the angle, in degrees, of displace-
ment between output voltage and output current. The
cosine of this number is an approximation of output power
factor.

Parameter Number

72

Parameter Type

Read Only

Display Units / Drive Units

1 Deg / 255 = 360 Deg

Factory Default

None

[Heatsink Temp]

This parameter displays the heatsink temperature of the
drive.

Parameter Number

70

Parameter Type

Read Only

Display Units / Drive Units

1

° C / Deg. C

Factory Default

None

Minimum Value

0

Maximum Value

255

° C

[Set Defaults]

Setting this parameter to “Defaults Init” resets all parame-
ters to their factory values.

Parameter Number

64

Parameter Type

Read and Write

Factory Default

“Ready”

Units

Display Drive

“Ready” 0

Display after function complete.

“Store to EE” 1

“Rcll frm EE” 2

“Default Init” 3

Resets all parameters to factory
settings.

Advertising