Securing the dryer tube to the monitor – ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 103

Advertising
background image

3-46

ADS FlowShark IS Manual

5. Connect each sensor cable to the appropriate port. Tighten each

connector in a clockwise direction until it clicks into place, and

verify that it is seated correctly.

6. For locations exhibiting the presence of hydrogen sulfide

and/or high moisture, provide added protection by wrapping

the connection with mastic tape.

7. Seal any unused connectors with a cap. If necessary, obtain

additional caps from the regional ADS representative.

Note:

An air valve is present in the center of the monitor

top. This valve exists only for testing purposes during the

manufacturing process. Do not attempt to fill the monitor
with air or pressurize the monitor!

Securing the Dryer Tube to the Monitor

Secure the dryer tube to the monitor in the following way:
1. Attach the dryer tube from the pressure depth sensor in the

vertical position to the monitor handle and chassis bolt using

cable ties.

Securing the dryer tube to the monitor using cable ties

2. Make sure the black end cap on the dryer tube is removed

before installing the monitor in the manhole.

Advertising