Intrinsic Safety

Intrinsic Safety is a protection classification for equipment that

ensures there are no conditions under which the equipment can

operate that could cause a release of energy sufficient to ignite a

hazardous gas or dust mixture. Devices that meet the low power,

current-limited design criteria are deemed Intrinsically Safe (IS).

Special design, testing, quality, and inspection rules apply to

manufacturers and users of IS equipment due to the critical nature

of the equipments’ deployment in hazardous areas. Areas in which

hazardous conditions can be expected to exist on a constant basis

are categorized (rated) as Class I, Division 1, in the USA and as

Zone 0 in Europe. Some U.S. cities and states have adopted the

NFPA (National Fire Protection Association) classification that

rates sanitary sewers as Class I, Division 1, areas. Many European

Union member states have classified their sanitary sewer systems as

Zone 0 or Zone 1 environments.
The FlowShark IS (Model 5000-IS1-xx-x) flow monitor is certified

to UL standards in the U.S. and to ATEX standards in Europe, and

it is approved for use in all classified (hazardous) sanitary sewer

and industrial hazardous areas. Many rest-of-world countries accept

the U.S. or ATEX certifications in lieu of their country-specific

requirements. It is the customer’s responsibility to ensure that
the certification(s) provided for the ADS equipment meets the
customer’s regulatory requirements.

Note:

FlowShark IS models include 5000-IS1-US-01,

5000-IS1-US, 5000-IS1-01, and 5000-IS1. In the

remainder of this manual, all models of FlowShark IS are

referred to as ADS Model 5000-IS1, unless otherwise

specified.