Activating the Monitor

After configuring the monitor, activate the monitor to initiate the

flow monitoring process based on the monitor configuration.

Monitor activation involves generating the activation data using the
Profile

software, downloading this data to the monitor, and

initiating flow data measurement and logging. The activation data

includes the current monitor firmware (embedded software) and

relevant portions of the LIF and other configuration parameters

necessary to ensure monitoring activities reflect the specific site

conditions and project requirements. The monitor requires these

files and information to properly measure and record the flow.

Note:

If the monitor has been deactivated (configured to

no longer wake-up and take measurements), the user must

communicate directly with the FlowShark IS monitor

through a serial connection before remote communications

can be resumed.

Monitor activation occurs through the Diagnostics tool in Profile.

Activate the monitor in the following way:
1. Select the monitor location you want to activate from the

Profile

main screen, and then click on the Diagnostics toolbar

button.

The Monitor Diagnostics dialog displays.