4-9

Gathering Tools and Materials

Obtain the following items to perform the installation:

Medium (No. 2) Phillips head screwdriver

Small (⅛-inch) flat blade screwdriver (to fit orange

communication cable terminal block)

Wire strippers (with holes to strip 16-, 18-, and 20- gauge

wires)

Small sharp side cutters (not the big cable tie trimmers used for

ring/monitor installs)

Vinyl electrical tape (not stretch tape)

Connecting the Communication Cable to the EMU

Before installing the EMU, verify that the communication cable and

the enclosure to house the EMU have been installed and at least 40

inches (102 cm) of communication cable is extending into the

enclosure. Then, connect the communication cable to the

Communication Interface/Barrier box inside the EMU in the

following way:

Warning:

Leave the communication cable disconnected from

the FlowShark IS while handling and terminating the cable into

the EMU. Adhere to the following steps precisely to avoid
damaging the Voltage Regulator PCB!