ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 117

Advertising
background image

4-14

ADS FlowShark IS Manual

SIM card seated in EMU modem

10. (applies only to battery-powered EMUs) Re-install the battery

pack in the EMU in the following way:

Install the battery pack into the battery compartment with

the cable facing out the left side of the compartment.

Connect the battery cable to the EMU power cable.

Note:

ADS offers EMUs that are equipped to run on

either battery power or external power directly from the

factory. However, an External Power Kit (ADS p/n 3800-

0181) is available through ADS for converting an existing

battery-powered EMU to receive power from an external

DC source. This kit includes detailed instructions for the

conversion.

11. (applies only to externally-powered EMUs) Attach the metal

connector from the 10-foot external power cable to the chassis

cable connector on the top of the EMU.

12. Replace the cover on the EMU, and securely tighten the four

plastic screws. Be sure the edges of the cover align with the

edge of the box and that no wires are trapped in the gasket.