Surcharge mount – ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 89

Advertising
background image

3-32

ADS FlowShark IS Manual

13. Measure the physical offset for the ultrasonic depth sensor (the

distance from the crown (top) of the pipe to the face of the

sensor).

Note:

This value will be necessary when configuring the

monitor using the Profile software.

Surcharge Mount

For a site that may experience surcharge conditions, mount the

ultrasonic depth sensor on the manhole wall using a special

surcharge bracket (ADS p/n I40-0010) directly above the opening

of the incoming pipe. This will ensure the sensor measures the range

above the flow surface at the location the flow enters the manhole.

Mount the ultrasonic depth sensor in the following way:

Note:

Handle the ultrasonic depth sensor with care, and

do not expose it to extreme temperatures for an extended

period of time. Keep the sensor in its protective packaging

until it is time for installation.

1. Determine the appropriate height at which to mount the

ultrasonic depth sensor portion of the surcharge bracket (The
sensor slides into the grooves of the mounting plate at the
lower portion of the bracket.

) When making this

determination, keep in mind that the maximum range of the

sensor is 12.5 feet (3.8 m).

Advertising